Documented specifications
Grandstream · Grandstream maintains an exact-model product page, current HT81x V2 guides and current V2 firmware records. Those records do not establish local inventory, global remaining support, provider approval or the build installed on an individual gateway.
| Specification | Documented value |
|---|---|
| Analog ports | 8 RJ11 FXS ports; eight jacks are not eight profiles, registrations or simultaneous calls Source ↗ |
| SIP profiles | 2 SIP profiles assignable across eight FXS ports; preserve every port-to-profile mapping Source ↗ |
| Network topology | Two 10/100/1000 Ethernet ports with integrated NAT-router behavior; topology and measured throughput remain deployment evidence Source ↗ |
| Line-test boundary | GR-909 line-test functions are documented; a test result is not a substitute for a completed call or fax Source ↗ |
| Fax capability | T.38 is listed for Fax-over-IP; negotiated mode and delivered pages require separate proof Source ↗ |
| Provisioning | TR-069 and automated provisioning are listed; ownership, fetch, apply and effective state remain separate Source ↗ |
| Firmware binary | Firmware 1.0.15.3 names ht81xv2fw.bin for HT812 V2, HT814 V2 and HT818 V2 Source ↗ |
| Downgrade boundary | After 1.0.9.3 or later, downgrade to 1.0.7.5 or earlier is not supported because of CPU-frequency adjustments Source ↗ |
Unlisted fields remain unverified. Platform compatibility and remaining support life require confirmation for the exact ordered model.
Resolve HT818 V2 identity before treating it as an HT818
Record HT818 V2 from the label and status page, plus part, hardware, serial or MAC and every software component version. Original HT818 and HT818 V2 share an eight-port role but are not interchangeable firmware or configuration targets. Exact V2 identity precedes any image, template or recovery action.
Current documentation and release notes do not establish installed state, local inventory, provider approval or support entitlement.
Map eight FXS ports onto two SIP profiles
HT818 V2 provides eight FXS ports and two SIP profiles. A physical port, selected profile, SIP User ID, Authenticate ID, registration and hunting membership remain distinct. A hunting group can alter outbound use of an active account, so a completed call from a member is not proof of independent registration.
Maintain an eight-row port table with attached device, profile, redacted identity, inbound policy, outbound policy and observed registration before making bulk changes.
Document the dual-port routed topology
HT818 V2 includes two Gigabit Ethernet ports and integrated NAT-router behavior. Record NET1 and NET2 roles, operating mode, cabling, address, gateway, DNS, time, upstream NAT, VLAN handling and any forwarding. Interface speed, router capability and application throughput are different measurements.
Do not copy HT802 V2’s single-interface assumptions into this topology or add a second routing boundary without a documented design.
Use port status and GR-909 as bounded evidence
The status page and eight phone LEDs expose port states, and the administration guide documents GR-909 line testing. Preserve the port, test, timestamp, result and connected device conditions. A pass or fail remains line-test evidence; it does not by itself prove ringing, caller ID, DTMF, registration, two-way media or fax delivery.
Compare one controlled port at a time so a device, cable, profile or gateway-port fault can be distinguished.
Keep the HT81x V2 image family explicit
Release 1.0.15.3 assigns ht81xv2fw.bin to HT812 V2, HT814 V2 and HT818 V2. It does not authorize original-HT818 firmware or the ht80xv2fw.bin used by HT801 V2 and HT802 V2. Preserve the exact model, current components, source, image name, release-record checksum, configuration and recovery path.
After an authorized update, confirm effective versions, all eight mappings, registrations and analog workflows rather than treating a reboot as completion.
Pilot density, hunting, calls and fax separately
Eight FXS ports concentrate the effect of power, network, template and PBX failures. Test cold boot, routed topology, provisioning, each port/profile assignment, intended hunting, inbound ring, outbound identity, DTMF, caller ID, two-way audio, restart and any required T.38 or G.711 fax path.
Respect the unsupported downgrade edge from 1.0.9.3 or later to 1.0.7.5 or earlier. No gateway, analog device, line test, network, account, call, fax or firmware change was tested for this reference.
Sources & applicability
Primary references for the technical details above. Operational examples and planning checklists are VoIP.info editorial guidance.
- Grandstream HT802 v2 product page ↗
- Grandstream HT802 V2 datasheet ↗
- Grandstream HT80x V2 Administration Guide ↗
- Grandstream HT80x V2 User Guide ↗
- Grandstream HT818 v2 product page ↗
- Grandstream HT818 V2 datasheet ↗
- Grandstream HT81x V2 Administration Guide ↗
- Grandstream HT81x V2 User Guide ↗
- Grandstream HT8xx V2 firmware 1.0.15.3 release notes ↗
Examples require adaptation to your topology. No live PBX or hardware testing is claimed.