Documented specifications
Grandstream · Grandstream maintains an exact-model product page, current HT80x V2 guides and current V2 firmware records. Those records do not establish local inventory, global remaining support, provider approval or the build installed on an individual adapter.
| Specification | Documented value |
|---|---|
| Analog ports | 2 RJ11 FXS ports; physical ports are not profiles, identities, registrations or simultaneous calls Source ↗ |
| SIP profiles | 2 SIP profiles through the two FXS ports; assignment and registration require per-port confirmation Source ↗ |
| Network boundary | One 10/100 Mbps Ethernet port; HT818 V2 dual-port routing behavior must not be copied to this model Source ↗ |
| Indicators | POWER, NET, PHONE1 and PHONE2 LEDs describe device and port state, not completed calls or analog-line quality Source ↗ |
| Fax capability | T.38 is listed for Fax-over-IP; negotiation and successful document delivery remain separate evidence Source ↗ |
| Provisioning | TR-069 and XML configuration are listed; fetch, apply, reboot and effective values remain separate Source ↗ |
| Firmware binary | Firmware 1.0.15.3 names ht80xv2fw.bin for HT801 V2 and HT802 V2 Source ↗ |
| Downgrade boundary | After 1.0.9.3 or later, downgrade to 1.0.7.5 or earlier is not supported because of CPU-frequency adjustments Source ↗ |
Unlisted fields remain unverified. Platform compatibility and remaining support life require confirmation for the exact ordered model.
Identify HT802 V2 before comparing another two-port ATA
Record the printed HT802 V2 identity, part and hardware version, serial or MAC, and the program, bootloader, core, base and CPE versions exposed by the status page. Original HT802, HT802 V2 and HT812 V2 can all appear in two-port discussions but have different network and firmware boundaries.
A current product page or release record establishes published documentation, not the installed build, local inventory, provider approval or remaining support.
Keep two ports, two profiles and account state separate
HT802 V2 exposes two FXS ports and documents two SIP profiles. Each port still needs an effective profile, SIP User ID, Authenticate ID, credential state and registration result. A dial tone, LED or working call on one port does not prove that the other independently registered or inherited the intended policy.
Map each physical port to its attached analog device, profile, identity, inbound treatment, outbound treatment and any hunting role before editing credentials.
Respect the single-interface network boundary
The HT802 V2 product and datasheet describe one 10/100 Mbps Ethernet interface. It is not the dual-Gigabit NAT-router topology documented for HT818 V2. Record switch port, link speed, VLAN source, address, gateway, DNS and NTP; do not troubleshoot a nonexistent LAN-versus-WAN port choice.
Network link, provisioning reachability, registration, signaling and bidirectional media remain separate checkpoints.
Treat LEDs and status as state hints
POWER, NET, PHONE1 and PHONE2 indicators help locate device, link and port state. A registered or off-hook indication does not measure analog voltage, ringing, cable continuity, caller-ID format, DTMF or audio. The IVR can announce the assigned address, but that does not establish SIP reachability.
For each port, preserve the status snapshot and then test the authorized analog device, cable, dial tone, inbound ring, digits, answer and two-way media in sequence.
Bind provisioning and firmware to HT80x V2
Grandstream documents TR-069, XML and several transfer protocols for provisioning and upgrades. Release 1.0.15.3 names ht80xv2fw.bin for HT801 V2 and HT802 V2; the similarly dated ht81xv2fw.bin belongs to HT812 V2, HT814 V2 and HT818 V2. File-name similarity is not model compatibility.
Preserve the requested file, response, image name, release-record checksum, apply or reboot event and effective component versions. Do not treat download or restart as success.
Accept calls and fax without hiding the downgrade limit
Grandstream lists T.38 and common analog telephony functions, but a checked option or successful registration does not prove a completed call or fax. Pilot inbound and outbound identity, ring, answer, DTMF, caller ID, two-way audio, fax negotiation when required, restart and configuration persistence.
A unit at 1.0.9.3 or later is not documented as downgradeable to 1.0.7.5 or earlier. No adapter, analog device, network, PBX, call, fax or firmware change was tested for this reference.
Sources & applicability
Primary references for the technical details above. Operational examples and planning checklists are VoIP.info editorial guidance.
- Grandstream HT802 v2 product page ↗
- Grandstream HT802 V2 datasheet ↗
- Grandstream HT80x V2 Administration Guide ↗
- Grandstream HT80x V2 User Guide ↗
- Grandstream HT818 v2 product page ↗
- Grandstream HT818 V2 datasheet ↗
- Grandstream HT81x V2 Administration Guide ↗
- Grandstream HT81x V2 User Guide ↗
- Grandstream HT8xx V2 firmware 1.0.15.3 release notes ↗
Examples require adaptation to your topology. No live PBX or hardware testing is claimed.